Analisis Dosis Efektif Pada Pemeriksaan CT-SCAN Kepala Kontras di Instalasi Radiologi Rumah Sakit Surya Husadha Denpasar

Authors

  • Juniaty Teroci Mamun Akademi Teknik Radiodiagnostik dan Radioterapi Bali
  • Kadek Yuda Astina Akademi Teknik Radiodiagnostik dan Radioterapi Bali
  • A. A. Aris Diartama Akademi Teknik Radiodiagnostik dan Radioterapi Bali

DOI:

https://doi.org/10.47861/usd.v2i1.675

Keywords:

effective dose, Diagnostic Reference Level (DRL), DLP, CT-Scan

Abstract

The effective dose is the dose on the CT-Scan that hits the patient's organs. The effective dose received by the patient should not exceed 3 standards that have been set both nationally and internationally. Nationally, the dose received by patients has been regulated in the Head of Bapeten Regulation on Diagnostic Reference Level (DRL). While internationally, the effective dose is regulated in the International Commission on Radiological Protection (IRCP). According to BAPETEN number 1211/K/V/2021 CTDIvol contrast head is 60mGy while DLP is 2500mGy.cm. The purpose of this study was to determine the amount of effective dose received by patients at the CT-Scan examination of the contrast head at the Radiology Installation of Surya Husadha Hospital Denpasar. The method used in this research is the quantitative method. Reference sources used in the preparation of this article include books, as well as articles in English and Indonesian scientific journals.

References

Ballinger PW, Frank ED, Merrill V. Merrill’s atlas of radiographic positions & radiologic procedures. Mosby; 2003.

Gede Agus Krisna Yogantara P, Ngurah Sutapa G, Made Yuliara I, Studi Fisika P, Matematika dan Ilmu Pengetahuan Alam F. Analisis Dosis Efektif Pada Pemeriksaan Computer Tomography (CT) Scan Kepala DiRSUD Sanjiwani Gianyar Effective Dose Analysis on Computer Tomography (CT) Head Scan at Gianyar Sanjiwani Hospital. Vol. 22, Akreditasi SINTA 4 Mulai. 2021.

Jurusan Fisika Fakultas Sains dan Teknologi I, Alauddin Makassar U. Studi dosis radiasi pada pemeriksaan Computer Tomography (CT) Scan dengan nilai Computer Tomography dose Indeks di Rumah sakit Bayangkara Makasar. Vol. 5. 2018.

Ballinger PW, Frank ED, Merrill V. Merrill’s atlas of radiographic positions & radiologic procedures. Mosby; 2003.

Kurniawan AN, Soesanti I. Evaluasi Nilai Noise Sebelum Dan Sesudah Kalibrasi Sebagai Salah Satu Wujud Kinerja Pesawat CT-Scan.

Hannigan Ken, Nolan W. Wicklow: history & society. Geography Publications; 1994. 1005 p.

Pengaruh Perubahan Faktor eksposi terhadap dosis Radiasi pada pemeriksaan Multislice computed Tomography 2021.

Downloads

Published

2023-12-19

How to Cite

Juniaty Teroci Mamun, Kadek Yuda Astina, & A. A. Aris Diartama. (2023). Analisis Dosis Efektif Pada Pemeriksaan CT-SCAN Kepala Kontras di Instalasi Radiologi Rumah Sakit Surya Husadha Denpasar. Usada Nusantara: Jurnal Kesehatan Tradisional, 2(1), 208–213. https://doi.org/10.47861/usd.v2i1.675

Similar Articles

1 2 > >> 

You may also start an advanced similarity search for this article.